Electrical Supplies

Quality Products for Safe, Reliable Installations

From new builds and renovations to repairs and upgrades, Rouberto Building Materials stocks a practical range of electrical supplies for electricians, contractors and competent homeowners. We carry electrical cable, conduit, distribution boards, switches, sockets, light fittings and associated hardware — all from trusted brands. Safety is everything when it comes to electrical work, and our team can help you identify the right products for compliant, safe installations.

Whether you’re wiring a new room, replacing a DB board or upgrading your lighting, we have what you need in Fontainebleau.

Products we offer

Electrical Supplies

Electrical Cable (PVC Insulated)

Single-core and multi-core PVC insulated copper cable in standard sizes for domestic and light commercial wiring. Common sizes include 1.5 mm² (lighting), 2.5 mm² (plug circuits), 4 mm² and 6 mm² (high-load circuits). Sold per metre or on drum.

Electrical Supplies

PVC Conduit & Fittings

White and grey rigid PVC conduit in 20 mm and 25 mm diameters for surface and concealed cable installations. Conduit boxes, couplings, bends and saddles stocked to match.

Electrical Supplies

Distribution Boards (DB Boards)

Single-phase and three-phase consumer units and distribution boards in a range of sizes for domestic and light commercial installations. Includes surface-mounted and flush-mounted enclosures.

Electrical Supplies

MCBs, RCCBs & RCBOs

Miniature circuit breakers (MCBs), residual current circuit breakers (RCCBs) and combined units (RCBOs) for overload and earth leakage protection. Available in standard Crabtree and compatible DIN rail formats.

Electrical Supplies

Switches & Sockets (Wall Plates)

Surface and flush-mounted switch plates and socket outlets in standard South African configurations. Available in white, stainless steel and brushed finishes. USB socket outlets also available.

Electrical Supplies

Light Fittings & Downlights

Recessed downlights, surface-mounted ceiling fittings, batten fittings and external security light fittings. Suitable for LED globes and downlight inserts.

Electrical Supplies

LED Globes & Tubes

Energy-efficient LED replacement globes in standard screw (E27) and bayonet (B22) bases, plus GU10 and MR16 downlight inserts. LED tube replacements for fluorescent batten fittings also stocked.

Electrical Supplies

Extension Leads, Adaptors & Junction Boxes

Multiple socket extension leads, adaptor plugs, junction boxes and cable connectors for general domestic use. SANS-compliant products stocked.

Brands we stock

Crabtree Logo
Legrand Logo
Osram Logo
Philips Logo
Clipsal Logo

Frequently Asked Questions

What gauge wire should I use for a plug circuit?

In South Africa, plug circuits (socket outlets) are typically wired using 2.5 mm² single-core PVC-insulated copper cable — three wires: live (red or brown), neutral (black or blue) and earth (green/yellow). Lighting circuits use 1.5 mm² cable. Higher-load circuits such as stoves (4–6 mm²) and geysers (4 mm² or larger depending on element rating) require heavier cable. The correct cable size depends on the circuit length, the load and the protective device rating. Always consult a registered electrician to confirm the correct specification for your installation.

An MCB (Miniature Circuit Breaker) protects a circuit against overcurrent and short circuit — it trips when too much current flows through it. An RCCB (Residual Current Circuit Breaker, also called an earth leakage circuit breaker or ELCB) detects current leaking to earth and trips to prevent electrocution — but does not protect against overload. An RCBO combines both functions in a single device, providing overload protection and earth leakage protection together. RCBOs are increasingly used in modern domestic installations for combined protection on individual circuits.

Yes. In South Africa, a Certificate of Compliance (COC) is a legal requirement for all notifiable electrical work, which includes new installations, additions to existing installations, and major repairs or alterations. The COC must be issued by a registered electrician (a wireman registered with the Department of Employment and Labour). Without a valid COC, your home insurance may be voided, and you may face difficulties when selling your property. Minor maintenance such as replacing a broken switch plate or a globe does not require a COC.

Installing or replacing a distribution board (DB board) constitutes notifiable electrical work under the Occupational Health and Safety Act and must be carried out by a registered electrician. The installation must be inspected and a Certificate of Compliance issued on completion. Attempting to install a DB board yourself without the correct registration is illegal, potentially dangerous and will likely invalidate your home insurance. We are happy to help you source the correct DB board and components, but we strongly recommend engaging a registered electrician for the installation.

Need Help Calculating Quantities?

Our team can help you identify the correct product for your installation.

Visit us in Fontainebleau, call us or WhatsApp a photo of what you’re looking for and we’ll track it down.